Configure the Device Monitoring¶
PLOSSYS Output Engine is able to monitor the physical statuses of devices via IPP. For this, the device has to have an IPP interface.
The IPP data requested from the device is stored in the database object physical
and will be overwritten whenever the device is checked.
In PLOSSYS Administrator, the device status can be displayed in an extra column and can be updated manually via menu item. The details of the device status are displayed in an extra dialog.
By default, the device monitoring is deactivated (NEVER
). The status of the device can be checked after specific actions, for example, after printing a job (AFTER_PRINT
).
Activate the Device Monitoring¶
For activating the monitoring for all devices, set the PRINTER_MONITOR_MODE
service key to the action when the devices are to be checked.
For activating the monitoring for a specific device, set the monitorMode
printer key to the action when the specific device is to be checked.
Relevant Keys¶
The following printer keys are relevant for the device monitoring:
-
connection
: URL of the printer connection -
monitorConnection
: IPP URL of the device for monitoring its status -
monitorMode
: If and when the status is checked for the specific device
The following service key is relevant for the device monitoring:
PRINTER_MONITOR_MODE
: If and when the devices' statuses are checked; this value is overwritten by the printer-specificmonitorMode
printer key.
Evaluation of the IPP URL¶
The IPP URL required for the device monitoring is evaluated in the following steps:
-
If the
monitorConnection
printer key is specified, this IPP URL is used for monitoring the status. -
Otherwise, it is checked if the
connection
printer key contains an IPP URL. If yes, this IPP URL is used for monitoring the status. -
If the
connection
printer key does not contain an IPP URL, the following modifications ofconnection
are tried. If one of these modifications can be used for the device monitoring, the value is saved asmonitorConnection
:http://<connection_server_name>:631
https://<connection_server_name>:443
https://<connection_server_name>:631
http://<connection_server_name>:631/ipp
https://<connection_server_name>:443/ipp
https://<connection_server_name>:631/ipp
http://<connection_server_name>:631/ipp/printer
https://<connection_server_name>:443/ipp/printer
https://<connection_server_name>:631/ipp/printer
-
If no IPP URL can be evaluated for the specific device, the monitoring for this device is disabled, that means the
monitorMode
printer key is set noNEVER
.